Czemu nie widzę żadnych pików?
Wstrzyknęłaś próbkę, czekasz 23 min i... płaska linia. Niepokój rośnie.
Wavelength 254 nm nie działa dla większości kwasów karboksylowych — użyj 210 nm.

We already hold the harmonised entry for this substance.
We have not issued a safety data sheet for it yet.
Free, and generated automatically from the sources listed on this page. No person has reviewed it, and it describes the substance in general — not your material, your process or your intended market.
Section 9 — physicochemical properties: 10 of 22 established.
We show what is established and name what is not. Classification and identity are complete on every card; section 9 is where public data is thin.
Données transcrites à partir de registres réglementaires et de la littérature spécialisée, avec indication de la source et de l'édition. Elles ne remplacent pas la fiche de données de sécurité du fournisseur. Les champs sans source enregistrée sont signalés comme tels.
Uzupełnienie tabeli „Właściwości fizykochemiczne (baza danych)” poniżej — powtórzone wartości pokazujemy tylko raz.
| Propriété | Valeur | Unité | Conditions | Source |
|---|---|---|---|---|
| Point d'éclair | 198.9 °C (NTP, 1992) | CAMEO Chemicals ↗ | ||
| Pression de vapeur | 0.0015 mmHg at 20 °C ; 0.007 mmHg at 30 °C (NTP, 1992)[1] | CAMEO Chemicals ↗ |
C1=CC(=CC=C1N)[N+](=O)[O-] InChI=1S/C6H6N2O2/c7-5-1-3-6(4-2-5)8(9)10/h1-4H,7H2
TYMLOMAKGOJONV-UHFFFAOYSA-N
Sources des données : CAMEO Chemicals
Dernière mise à jour : 2026-08-27
| Formule brute | C6H6N2O2[1] |
| Masse moléculaire | 138.12 g/mol[1] |
| Point de fusion | 147.5 °C[1][2] |
| Point d'ébullition | 332.22 °C[1] |
| Densité | 1.4 g/cm³ |
| LogP (lipophilie) | 1.4[1] |
| Nom IUPAC | 4-nitroaniline[1] |
| SMILES | C1=CC(=CC=C1N)[N+](=O)[O-][1] |
| InChIKey | TYMLOMAKGOJONV-UHFFFAOYSA-N[1] |
Synonymes: 4-NITROANILINE · p-Nitroaniline · 100-01-6 · 4-Nitrobenzenamine · p-Nitraniline
Sources des données : PubChem (NLM/NIH)
Dernière mise à jour : 2026-08-27
Les spectres sont récupérés à la demande depuis 9 sources. Chaque spectre est enregistré dans notre base — la prochaine ouverture = zéro requête vers l'API externe. Téléchargez JCAMP-DX / CSV / PNG pour chaque spectre sans avoir à chercher.
Source de référence — pas d'API publique. Ouvrir dans une base externe :
🔗 IR/NMR/MS (SDBS) →Source de référence — pas d'API publique. Ouvrir dans une base externe :
🔗 JP Monograph →Source de référence — pas d'API publique. Ouvrir dans une base externe :
🔗 WHO INN →Source de référence — pas d'API publique. Ouvrir dans une base externe :
🔗 DOAJ →Classification GHS/CLP — Règlement (CE) n° 1272/2008 + UN GHS Rev. 9 (2021).
✓ Classification harmonisée conformément à l'annexe VI du règlement CLP (CE) 1272/2008 (classification officielle, contraignante). Numéro d'index : 612-012-00-9.
Référence (Chicago) : European Chemicals Agency. "o-nitroaniline, Index No. 612-012-00-9." In Table 3 of Annex VI to Regulation (EC) No 1272/2008 (CLP Regulation), 23rd Adaptation to Technical Progress (harmonised list as of 2026-07-07). Helsinki: European Chemicals Agency, 2026. https://echa.europa.eu/information-on-chemicals/annex-vi-to-clp.
Traductions : Règlement CLP (CE) 1272/2008, Annexe III et IV. Données : PubChem/NLM.
Références collectées dans tous les onglets du Safety Hub. CAS : 100-01-6 ·
PubChem ↗
Les onglets possédant leurs propres références (Emergency, PPE, Storage, Waste) contiennent des entrées bibliographiques supplémentaires au sein de leurs sections respectives.
Collez une série de mesures répétées (CSV ou un nombre par ligne). Le calculateur calculera la moyenne, l'écart-type, l'IC à 95 %, et détectera les valeurs aberrantes (Grubbs + Dixon Q).
x̄ = Σxᵢ / n — moyenne arithmétiques² = Σ(xᵢ - x̄)² / (n-1) — variance de l'échantillons = √s² — écart-typeRSD% = (s / x̄) × 100% — écart-type relatifCI₉₅ = x̄ ± t(0.05, n-1) × s / √n — Student's tG = |xᵢ - x̄| / s — test de GrubbsQ = |xsuspect - xnearest| / |xmax - xmin| — Dixon Q-testSource : ICH Q2(R2) Validation of Analytical Procedures · ICH PDF ↗
Choisissez un tampon dans la liste de 20 systèmes courants → saisissez le pH cible → vous obtiendrez une recette exacte avec les masses à peser.
Sources : ADR 2025 ↗ · IATA DGR ↗ · IMDG Code ↗
Planifiez l'ensemble de votre projet de laboratoire : ajoutez des expériences avec réactifs, réplicats et durée. Vous obtiendrez un diagramme de Gantt, une liste d'achats (avec des liens vers la boutique !), un budget avec une marge de 10 % et une matrice de risques GHS.
💡 Connectez-vous pour enregistrer des projets. Sans connexion, vous pouvez calculer mais pas enregistrer.
100-01-6
— multi-criteria ranking (W12): 30% citations · 20% actualité · 20% thème · 15% historique · 15% open access.
Scénarios spécifiques à la molécule, dépannage et références bibliographiques
Przewidywane parametry dla tej molekuły (CAS 100-01-6) bazują na literature-backed models (Snyder-Dolan LSS, Neue pore-size rules).
⚠️ Predykcje oparte na modelach chemometrycznych — wymagają walidacji z rzeczywistym pomiarem. Confidence: low/medium/high zależnie od dostępnych deskriptorów.
Name + CAS + Grade + Role in method
HPLC vs LC-MS vs Far UV — when to use which
Volumes required for the selected method
| Property | Acetonitrile (ACN) | Methanol (MeOH) |
|---|---|---|
| Viscosity (20°C) | 0.37 cP | 0.59 cP (+59%) |
| Back Pressure | ~150 bar | ~210 bar (+40%) |
| UV Cutoff | 190 nm | 205 nm |
| Elution Strength | Stronger | Weaker |
| Price (typical) | 115 zł/L | 70 zł/L (-39%) |
H = A + B/u + Cu
Higher viscosity (MeOH) → lower optimal flow rate → longer runtime.
Common Mistake: Using old buffer (>1 week room temp) = pH drift + microbial growth → ghost peaks.
Source: ResearchGate
Source: r/chemistry
Source: Snyder LSS Model
Source: Chromatography Forum
| # | Time | %B start | %B end | Duration | Slope (Δ%B/min) | Step |
|---|
💡 Rule of thumb: slope 2-5 %B/min daje best peak shape · dwell vol = puste rurki od pompy do kolumny (sprawdź blank run bez kolumny) · k*·t0 ≥ 3 dla Rs ≥ 2.0.
Log k = log kw − S·φ, gdzie φ = fraction B. Optymalny gradient: Δφ ≈ 0.6–0.8 per 5 t0. Dla kolumny 250×4.6mm @ 1 mL/min → t0 ≈ 2 min → gradient 10–12 min.
Source: Predictive modeling
Source: Snyder Seminar
Source: LCGC
150×4.6 mm · 3.5 μm · pH 2–9
150×4.6 mm · 3.5 μm · pH 1–12 (high pH)
100×4.6 mm · 2.6 μm core-shell · fast
Source: Phenomenex Knowledge
Source: Agilent App Notes
Source: Phenomenex Guide
| Parameter | Value | Why |
|---|---|---|
| Wavelength | 210 nm (primary) + 254 nm (aromatic) | Uniwersalne dla COOH/C=O |
| Bandwidth | 4 nm | Balans czułości vs selectivity |
| Response time | 0.5 s | Zgodne z peak width ~5 s |
| Reference λ | 360 nm, bw 100 nm | Kompensacja baseline drift |
| Parameter | Acceptance | Formula |
|---|---|---|
| Resolution (Rs) | ≥ 2.0 | 2(tR2 − tR1) / (w1 + w2) |
| Tailing factor (Tf) | ≤ 1.5 | W0.05 / (2·f) |
| Plates (N) | ≥ 5000 | 16·(tR / w)² |
| RSD (6 injections) | ≤ 2.0% | σ / μ × 100% |
| Linearity (R²) | ≥ 0.9990 | 80–120% spec, 5 levels |
Metoda zaprojektowana zgodnie z poniższymi regulacjami. Kliknij badge aby zobaczyć szczegóły compliance.
United States Pharmacopeia General Chapter — wymagania dla HPLC systemów.
Reference: USP-NF 2024, General Chapter <621> Chromatography
International Council for Harmonisation — walidacja metod analitycznych.
Reference: ICH Q2(R1) Validation of Analytical Procedures, 2005
European Pharmacopoeia — chromatographic separation techniques.
Reference: EP 11.0, Chapter 2.2.46
Japanese Pharmacopoeia — zgodne z harmonizacją USP/EP po 2020.
Reference: JP 18th Edition, General Chapter 2.00
Current Good Manufacturing Practice dla produktów farmaceutycznych (USA).
Reference: 21 CFR Part 211 — Current Good Manufacturing Practice
Międzynarodowy standard dla kompetencji laboratoriów testowych.
Reference: ISO/IEC 17025:2017
Porównanie naszej zalecanej metody vs USP Monograph vs Literatura PubMed vs Vendor Application Note.
| Parametr | Nasza metoda ★ | USP <621> | Literatura | Vendor (Agilent) |
|---|---|---|---|---|
| Kolumna | Zorbax Eclipse Plus C18 150×4.6 mm | L1 (C18, bonded, 5 μm) | n/a (brak PubMed refs dla tego CAS) | Zorbax SB-C18 150×4.6 mm |
| Wielkość ziarna | 3.5 μm | 5 μm (USP default) | — | 5 μm |
| Faza A | 10 mM NH₄HCO₃ pH 7.0 | Phosphate buffer pH 2.5 | — | 0.1% TFA w H₂O |
| Faza B | Acetonitryl HPLC grade | Acetonitryl / Methanol | — | Acetonitryl / 0.1% TFA |
| Gradient | 5 → 95% B w 15 min (linear) | Isocratic (preferowane w USP) | — | 10 → 90% B w 20 min |
| Flow | 1.0 mL/min | 1.5 mL/min | — | 1.0 mL/min |
| Temperatura | 30°C | 25°C | — | 40°C |
| Detekcja | UV 210 nm + 254 nm | UV 254 nm (standard USP) | — | DAD 210/254 nm |
| Runtime | 23 min | 30 min | — | 25 min |
| Rs (typ.) | 2.3 | ≥ 2.0 | — | 2.1 |
| Walidacja | USP <621> + ICH Q2(R1) | USP <621> obligatoryjnie | — | Application note only |
| Koszt solventów/run | ~5 zł/run | ~7 zł/run | — | ~6 zł/run |
Wybierz symptom → zobacz najbardziej prawdopodobne przyczyny → kliknij aby zobaczyć fix.
Diagnoza: Column oven włączony? 30°C?
Fix: Włącz column thermostat 30°C.
Diagnoza: Method → DAD → Primary λ — sprawdź czy 210
Fix: Zmień wavelength na 210 nm dla związków bez aromatyki.
Diagnoza: Status lampki na detektorze — zielona?
Fix: Włącz lampę, czekaj 3-5 min warm-up.
Diagnoza: Czy próbka >0.1 mg/mL?
Fix: Zwiększ stężenie 10× do 1 mg/mL.
Diagnoza: Czy filtrujesz próbki 0.22 μm?
Fix: Wymień column frit LUB guard column. W przyszłości filtruj każdą próbkę.
Diagnoza: Jaki slope %B/min?
Fix: Zwolnij gradient: 13→56% B w 20 min zamiast 15 min.
Diagnoza: Flow 1.5 mL/min?
Fix: Zmniejsz do 0.8 mL/min.
Diagnoza: Zmierz pH bufora — 7.0±0.2?
Fix: Zrób fresh buffer 10 mM NH₄HCO₃ pH 7.0.
Diagnoza: Liczba wstrzyknięć? >2000?
Fix: Regeneruj: flush 100% ACN 30 min, potem 100% MeOH 30 min.
Diagnoza: Fronting + tailing jednocześnie? Stężenie >5 mg/mL?
Fix: Zmniejsz inj. vol 10→5 μL lub rozcieńcz 2×.
Source: ICH Q6A
Source: FDA Guidance
Source: USP Online
Cząstki >0.22 μm zatykają inlet frit kolumny. Pressure rośnie +50 bar per 100 wstrzyknięć. Column lifetime spada z 2000 do 500 wstrzyknięć. Filter cost: 2 zł. Column cost: 1800 zł.
Full protocol with all parameters
GMP-compliant SOP template
ICH Q2(R1) validation template
All references in BibTeX format
Véritables mésaventures de chimistes — ce qui s'est passé, ce qui a aidé, ce qu'il faut éviter.
Wstrzyknęłaś próbkę, czekasz 23 min i... płaska linia. Niepokój rośnie.
Wavelength 254 nm nie działa dla większości kwasów karboksylowych — użyj 210 nm.
FDA inspection Q3 2025. Warning Letter: "Empower audit trail disabled w 3 sekwencjach 2024-12". Investigation: stary operator który odszedł, miał privilege „Disable audit" do troubleshoot. NIKT nie wyłączył mu privileged after departure.
Privileged access review MIESIĘCZNIE. Disable audit trail nigdy nie powinno być włączone na prod. HR offboarding MUSI triggerować IT revocation access. Koszt: 483 form + 6 miesięcy remediation.
Masz doświadczenie z tą metodą? Problem który rozwiązałaś? Wpadka której chcesz oszczędzić innym? Napisz — po akceptacji moderatora pojawi się tutaj jako „real case".
Toutes les sources scientifiques citées dans les accordéons ci-dessus pour le CAS 100-01-6. Format : Chicago Manual of Style, 17e éd., système Auteur-Date.